ModelHPS300-100, 300V 100A 30KW DC Power Supply Datasheet

Item

Specifications

Input

 

Input Voltage

3P4W, 3-Wire + Earth-Ground, Operating range

342Vac ~528Vac

Input Frequency

47 ~ 63 Hz

Input Current

42A/Phase @ 440Vac

Input Line Current THD

5% Max. > 20% load current

Input Inrush Current

< 84A/Phase

Efficiency

94%  @ 100% load

Power Factor

0.98  @ 100% load

Output

 

Output Voltage

Nominal 300V±1%

290V~310V with load, Programmable

Output Current

Nominal 100A, 105A Max.

Output Power

Nominal 30KW, 32KW Max.

Line/Load Regulation

2.5% Max. from zero load to 100% load over full AC Input range

Load Transient Response

DC 300V±5% ,Recover within 5ms at 50% to 100% or 100% to 50% load change

Ripple and Noise

< 300mVp-p at 100% load

Soft-Start Rise Time

200~400ms

Parallel Operation

Up to 10 units, Current share per unit within ±10% where the nominal current per unit is > 50% load current.  No damage or shut-off unexpectedly

Protection

 

Over Current Protection

140A Hardware Protection
50~140A  Programmable Protection

AC Line drop/Phase Loss

Typical 1 cycle ride-through on all three phases

Under Voltage Protection

260~310V Programmable Protection, Accuracy ±2V

Over Voltage Protection

330V hardware Protection
290~330V Programmable Protection, Accuracy
±2V

Over Temperature Protection

90at sensor point, Protected against Fan Fault or excessive ambient temperature

 

Item

Specifications

General

 

Operating Temp. (ambient)

-10~50

Storage Temp. (ambient)

-20~65

Humidity

Relative humidity 5%~95%, non-condensing

Altitude

Operating:   1,500m above sea level with no derating

                        3,000m above sea level with 40 derating

                        5,000m above sea level with 30 derating

Non-operating: 15,000m above sea level

Dimension

3U x 19 inches x 800mm approx. (H x W x D)

Weight

< 60KG

Temperature Test

High: 810E Method 501 Procedure

Low:  810E Method 502 Procedure

Vibration Test

810C Method 514 Procedure with anti-shock rack

Lightning Surge Test

IEC 61000-4-5

Remote Digital Interface

LAN and RS232

Other